User Tools

Site Tools


bioimpedance

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
bioimpedance [2014/04/22 08:21]
127.0.0.1 external edit
bioimpedance [2018/07/26 12:50]
Admin [Computational experiments] add youtube video
Line 26: Line 26:
  
 Computed current lines in the human body\\ Computed current lines in the human body\\
-{{flowplayer>playground:​test1.mp4 240,320 autoBuffering}} +{{youtube>_K6qc-HvTPI?​size=240x320&​autoplay=1&​rel=0}}
 ===== Sensitivity field distributions for segmental BIA ===== ===== Sensitivity field distributions for segmental BIA =====
 Sensitivity field distribution for some electrode combinations for the assessment of body regions in segmental BIA Sensitivity field distribution for some electrode combinations for the assessment of body regions in segmental BIA
Line 52: Line 51:
   - Danilov A.A., Kramarenko V.K., Nikolaev D.V., Rudnev S.G., Salamatova V.Yu., Smirnov A.V., Vassilevski Yu.V. //​{{:​bioimpedance:​icebi-2013-danilov.pdf|Sensitivity field distributions for segmental bioelectrical impedance analysis based on real human anatomy}}// %%//%% J. Phys.: Conf. Series, 2013, 434: 012001 [[http://​dx.doi.org/​10.1088/​1742-6596/​434/​1/​012001| DOI: 10.1088/​1742-6596/​434/​1/​012001]]   - Danilov A.A., Kramarenko V.K., Nikolaev D.V., Rudnev S.G., Salamatova V.Yu., Smirnov A.V., Vassilevski Yu.V. //​{{:​bioimpedance:​icebi-2013-danilov.pdf|Sensitivity field distributions for segmental bioelectrical impedance analysis based on real human anatomy}}// %%//%% J. Phys.: Conf. Series, 2013, 434: 012001 [[http://​dx.doi.org/​10.1088/​1742-6596/​434/​1/​012001| DOI: 10.1088/​1742-6596/​434/​1/​012001]]
   - Danilov A.A., Kramarenko V.K., Nikolaev D.V., Yurova A.S. //​{{:​bioimpedance:​rjnamm-danilov-2013.pdf|Personalized model adaptation for bioimpedance measurements optimization}}//​ %%//%% Russ. J. Numer. Anal. Math. Modelling, 2013, Vol. 28, No. 5, P.459–470. [[http://​dx.doi.org/​10.1515/​rnam-2013-0025|DOI:​ 10.1515/​rnam-2013-0025]]   - Danilov A.A., Kramarenko V.K., Nikolaev D.V., Yurova A.S. //​{{:​bioimpedance:​rjnamm-danilov-2013.pdf|Personalized model adaptation for bioimpedance measurements optimization}}//​ %%//%% Russ. J. Numer. Anal. Math. Modelling, 2013, Vol. 28, No. 5, P.459–470. [[http://​dx.doi.org/​10.1515/​rnam-2013-0025|DOI:​ 10.1515/​rnam-2013-0025]]
 +  - Yu.V. Vassilevski,​ A.A. Danilov, T.M. Gamilov, Yu.A. Ivanov, R.A. Pryamonosov,​ S.S. Simakov. //​{{::​rjnamm_vassilevski15.pdf|Patient-specific anatomical models in human physiology}}//​ %%//%% Russ. J. Numer. Anal. Math. Modelling, 2015, Vol. 30, No. 3, P.185–201. [[http://​dx.doi.org/​10.1515/​rnam-2015-0017|DOI:​ 10.1515/​rnam-2015-0017]]
bioimpedance.txt · Last modified: 2021/03/18 19:30 by Alexander Danilov